BPL DF2509 Monophasic Defibrillator with Recorder
BPL Monophasic Defibrillator : Product description
BPL DF2509 Monophasic Defibrillator (Recorder) : Key Features
LCD with Backlight:
DF 2509 defibrillator has a 5.7-inch monochrome LCD with backlight, it delivers reliable and accurate reading with better contrast and brightness.
Event Recording:
The BPL DF 2509 keeps a record of all the important up to 24 events during its use. This helps doctors review what happened during a cardiac emergency, so they can make better decisions.
Thermal Printing:
This DF 2509 monophasic defibrillator can print out important information on paper. This printout provides a clear record of the treatment and the patient's condition, which can be helpful for future reference.
Visual and Audible Charge Indicator:
The device has both visual and sound signals to show when it’s ready to give a shock. This ensures that you know exactly when it’s time to use the defibrillator.
Charging Time:
The time it takes for the defibrillator to charge up is quick. This means it can be ready to help in a short amount of time after being used.
Enhanced Battery Usage:
The battery in the BPL DF 2509 defibrillator lasts longer, can deliver more than 100 shocks of 360 joules. This means the defibrillator is ready for use whenever it’s needed.
BPL DF 2509 Monophasic Defibrillator : Technical Specifications
Brand | BPL Medical |
Model | DF2509 |
Type | Monophasic defibrillator |
Display Size | 5.7 inch STN LCD Display |
Energy Level | 2J to 360J |
Event Recording | 24 hrs |
Battery Type | Rechargeable Sealed Lead Acid battery |
Battery Capacity | 12V, 4.5AH; 100 discharges of 360 joules or 7 hrs of monitoring with a fully charged new battery |
Weight | 10.5 kgs (with battery & paddle) |
Dimension | 26 (W) X 28 (D) X 25 (H) mm |
BPL DF2509 Monophasic Defibrillator : Certifications
BPL DF2509 Monophasic Defibrillator is an ISO Certified Company.
BPL DF2509 Monophasic Defibrillator : Application Area
- ICU (Intensive Care Unit)
- Emergency Departments
- Ambulance Services
- Surgical Settings
- Cardiovascular
BPL 2509 Defibrillator : Highlights
- Deliver shock from 2 to 360 joules.
- BPL DFD 2509 defibrillator can deliver 100 shock of 360 joule power with a fully charged new battery.
- This has even recording feature record and print pre- & post-event.
- DF 2509 defibrillator has a thermal printing option to print data using a high resolution thermal printer.
BPL DF 2509 Defibrillator : Supplies List
- Defibrillator Paddles (Adult & Pediatric)
- Disposable Electrodes
- Patient Cable (3 Lead)
- Mains Cable (Power Cord)
- Cardijelly
- Earth Cable
- Accessory Bag
- User Manual
- Recording Paper
BPL DF 2509 Monophasic Defibrillator (With Recorder) : Other Features
- LCD display with backlight.
- Take less than 5 second to charge to 360 joules.
- Visual and audible charge indicator.
- Rechargeable seal acid battery.
- DF 2509 defibrillator can record the event up to 24 events.
BPL DF 2509 Defibrillator : Quick Tips
- Regularly check the battery to ensure the battery is fully charged and in good condition.
- To track and review the details, use the event recording feature of BPL DF 2509.
- Pay attention to the visual and audible charge indicators to know when the defibrillator is ready to deliver a shock.
- After use, allow the defibrillator to recharge quickly. It will be ready for the next emergency in no time.
BPL DF 2509 Defibrillator : Direction for Use
Get Ready:
Safety First: Make sure the area is safe and dry. Remove any water or anything that could conduct electricity.
Check the Machine: Make sure the defibrillator is working, and the battery is charged.
Turn On the Machine:
Power Up: Press the button to turn on the DF 2509 defibrillator. Follow the instructions on the screen.
Prepare the Patient
Position Them: Lay the patient on their back on a flat surface.
Expose the Chest: Take off any clothes covering the chest. Make sure the chest is clean and dry.
Attach the Pads:
Place the Pads: Put the electrode of BPL DF 2509 defibrillator on the patient’s chest. One goes on the upper-right side and the other on the lower-left side.
Check the Heartbeat:
Start Checking: Press the button to start checking the heart’s rhythm. The defibrillator will decide if a shock is needed.
Give a Shock (If Needed):
Prepare for Shock: If the DF 2509 defibrillator says a shock is needed, make sure no one is touching the patient.
Deliver Shock: Press the button to charge the defibrillator. After it’s charged, press the shock button to deliver the shock.
After the Shock:
Start CPR: Start CPR immediately if needed. Follow the usual steps for CPR.
Watch the Patient: Keep an eye on the patient and be ready to give another shock if needed.
BPL Monophasic Defibrillator : Specifications
- 1 Year
- Inbuilt Thermal Printer
- 5.7 Inch
BPL Monophasic Defibrillator : Product reviews
No reviews found