Contec 12 Channel ECG Machine : Product description
Contec 1200G is a 12 channel electrocardiograph which gathers 12-lead ECG signals simultaneously and print out the ECG waveforms with an inbuilt thermal printer. It is designed for medical establishment like hospitals, clinics, medical institutions. The machine provides 12-Lead ECG with signal processing technology.
Use:
It can is used by medical institutions like hospitals, clinics, medical colleges, Cardiac diagnostic centers to record human ECG signals, collect and extract ECG waveforms.
Contec 1200G Digital 12 Channel ECG Machine : Technical Specifications
Product Name | Contec 1200G 12 Channel ECG Machine, Touch Screen |
Brand | Contec |
Model Name/Number | 1200G |
Input Mode | Floating and defibrillation protection |
Frequency Response | 0.05Hz ~ 150Hz (-3dB ~ +0.4dB) |
CMRR | >60dB, >100dB (with filter) |
Time Constant | ≥3.2s |
Patient Leak Current | <10µA |
Calibration Voltage | 1mV |
Sensitivity | 2.5, 5, 10, 20, 40 mm/mV ±5% |
Noise Level | ≤15µVp-p |
Input Circuit Current | ≤50nA |
Input Impedance | ≥50MΩ |
Sampling Accuracy | 12-bit |
Safety Classification | Class I, Type CF, defibrillation-proof applied part |
Recording Mode | Thermal printing system |
Paper Size | 210 mm (W) × 20 m (L) |
Sampling Frequency | 1000Hz |
EMG Interference Filter | 25Hz/35Hz (-3dB) |
Power Frequency Filter | AC 50Hz/60Hz (-20dB) |
Paper Speed | Auto: 25, 50 mm/s, ±5% |
Power Supply | AC: 100V~240V (50/60Hz) |
Battery | DC: 14.8V/3500mAh, rechargeable lithium battery |
Dimensions | 340 mm(L) × 320 mm(W) × 85 mm(H) |
Weight | 3.2Kg |
Sales Package Content:
1x Contec 1200G Main Unit
1x ECG Cable
1 Set x Bulb Electrode
1 Set x Clamp Electrode
1 Set x Power Cable
1 Set x Earthing Cable
1 x User Manual
Safety Information:
Read the manual/instruction leaflet carefully before use. We provide user manual in sales package.
- It's recommended to use only quality ECG paper designed for Contec 1200G. Give preference to original paper.
- Avoid spilling liquids onto the unit to prevent damage.
- Properly clean the unit, patient cables, and electrodes after each use.
- Keep patient cables away from sharp-edged materials to avoid cutting or fraying.
- Ensure that wires are not unnecessarily extended to prevent tangling or tripping hazards.
- Regularly inspect accessories for cracks or damages.
- Refrain from using abrasive detergents or chemicals that may damage the unit.
- Check all connectors outside the machine to ensure they are securely attached.
- Verify that the ECG paper is properly loaded before operation.
- Avoid operating the machine without paper to prevent damage to the printer-head.
- Check the battery status before operation and refrain from using the Contec 1200G when the battery is low to avoid interruptions during use.