Simtek Medical Infutek 405ex Syringe Pump | LCD Display, Automatic Rate Calculation, Drug Library
Simtek Medical Infutek 405ex Syringe Pump : Product description
The Simtek Medical Infutek 405ex Syringe Pump is a reliable and versatile medical device that comes equipped with several key features to ensure efficient and safe delivery of medication. One of its most notable features is the convenience of front loading, which allows for easy access to the syringe without having to move the entire device.
Another useful feature is the utility of stacking, which enables multiple units to be stacked on top of each other for compact storage and efficient use of space. The drug library feature allows for quick and easy visualization of drug names, volume infused, infusion time, and flow rate on the LCD/LED displays.The device also has a body weight rate calculation function, which ensures that the medication is delivered at the appropriate dosage based on the patient's weight. The bolus with safety time lock feature allows for safe and controlled administration of medication, while the adjustable target volume with pre-alarm function provides added flexibility in medication delivery.
The Simtek Medical Infutek 405ex Syringe Pump is programmable to accept any brand of syringe, making it easy to use with different types of medication. Additionally, it comes with an automatic rate calculation function with volume and time limits, ensuring accurate and consistent delivery of medication.The device can be upgraded to a double loop PCA (Patient Controlled Analgesia) system, which allows patients to self-administer pain medication within prescribed limits. Finally, the pump is housed in an impact-resistant strong cabinet, which helps protect the equipment during accidental mechanical impact. Overall, the Simtek Medical Infutek 405ex Syringe Pump is a highly efficient and reliable device that can significantly improve the delivery of medication in a clinical setting.
Simtek Syringe Pump, Infutek 405ex :-
1. Convenience of Front Loading
2. Utility of Stacking
3. Drug Library
4. Allows at a Glance Visualization of Drug Names, Volume Infused, Infusion Time & Flow
5.Rate On LCD / LED Displays
6. Body Weight Rate Calculation
7. Bolus with Safety Time Lock
8. Adjustable Target Volume With Pre alarm
9. Programmable to Accept Any Brand of Syringe
10. Automatic Rate Calculation with Volume and Time Limit
11. Upgradable to Double Loop PCA (Optional)
12. Impact Resistant Strong Cabinet to Protect the Equipment During Accidental Mechanical Impact
PRODUCT SPECIFICATIONS :-
Brand | : | Simtek |
Model | : | Infutek 405ex |
SYRINGE | : | 10, 20, 30, 50/60ML, 5ML(Optional), 100ML(Optional) |
FRONT LOADING OF SYRINGE | : | Syringe size is automatically detected |
ACCEPTABLE SYRINGES | : | All available standard brands of syringes. Custom Programmable to any brand syringe. |
FLOW RATE RANGE | : | 0.1-999.9ml/Hr(Depending on syringe size) |
INFUSED VOLUME RANGE | : | 0.1-999.9ml |
BOLUS RATE & VOLUME | : | 300-999.9ml/hr(Depending on syringe size), Volume is Programmable by user |
BOLUS INTERVAL | : | A minimum interval of time can be preset between two Bolus dose to avoid accidental over infusion , 1min to 24 Hrs. |
KVO | : | To Prevent Needle Clogging With Programmable Kvo Rate |
OCCLUSION | : | Low, Medium, High Levels |
PUMP STACKING | : | Multiple Pump Stacking with Normal or Optional Single Power Cord. Facility of Stacking of 2-3 Pumps with built in Stacking Clips, ensures more useful group application & portability in & around the hospital premises. |
BODY WEIGHT MODE | : | Delivery rate is calculated Automatically based on Volume & time preselection or on values entered for patient (Optional) bodyweight with drug parameters. |
ALARMS | : | Occlusion , End of syringe, Low Battery, syringe displaced, No syringe, Wrong syringe, Pre Alarm for END, invalid rate, target Volume, Target Time, Target volume Pre-alarm, Mains Failure Alarm. |
ACCURACY | : | Volume : +/-1%, Time : +/-1% |
TIME LIMIT | : | Time from 00 : 01 to 23 : 59(hrs : min )or more if specially demanded |
VOLUME LIMITS | : | From 0.1ml to capacity of the syringe. |
POWER | : | 220VAC, +/-10%, 50/60Hz 12VA |
BATTERY TYPE | : | Ni Mh, 12V, 1300 mAHr |
BATTERY BACK-UP | : | 5-6Hrs(Typ. ) @5ml/Hr. Or more if specially demanded |
BATTERY RECHARGING | : | 20Hrs. For full Charging |
STANDARDS | : | Tested as per IEC 60601. 1 60601-1-2 60601-2-24 |
DISPLAY | : | Premium look with exclusive Blue Color Display (Only in Infutek 405 Ex) |
RS485 / RS232PORT | : | For Computer Interface Central Monitoring Station (Only in Infutek 405 Ex) |
PCA (Optional) | : | Upgradable to PCA with Double Loop Safety for PCA dose and time (Only in Infutek 405 Ex) |
Sales package Content:
Simtek Medical Infutek 405ex Syringe Pump
Power Cord
User Manual
Simtek Medical Infutek 405ex Syringe Pump : Specifications
- 1 Years
Simtek Medical Infutek 405ex Syringe Pump : Product reviews