Yonker YK8000C Multipara Patient Monitor
Please sign in so that we can notify you about a reply
Yonker Patient Monitor : Product description
The Yonker YK-8000C Multipara Patient Monitor is the perfect device for nurses and other medical professionals who need to keep track of a patient's vital signs. With its 12.1-inch TFT screen, it provides a clear display of all ECG, RESP, SPO2, NIBP, PR, TEMP, IBP, ETCO2 data.
Features :
- 8 parameters (ECG, RESP, SPO2, NIBP, PR, TEMP, IBP, ETCO2)+ Fully independent module (Independent ECG + Nellcor + Suntech blood pressure + dual IBP);
- 3 level audio/visual alarm function;
- 12.1 inch color LCD touch screen supports multiple language modes;
- Built-in high capacity lithium battery (4 hours) for emergency power outage or patient transfer;
- Automatic data storage function: supports nearly 96 hours of historical monitoring data query;
- Anti-fibrillation, anti-high-frequency electrosurgical interference, support diagnosis, monitoring, surgery three monitoring modes, support wire or wireless central monitoring system;
- Optional printing function, suitable for operating room, ward and other scenes.
Standeard Parameters :
NIBP :
- Method: Oscillometry
- Measure mode: Manual, Auto, STAT
- Measure interval in auto mode : 1~5/10/15/30/60/90/120/180/240/480 min
- Measure period in STAT mode : 5 min
Pulse rate range: 40 ~ 240bpm
Measure & alarm range:
Adult :
- SYS 40 ~ 280mmHg
- DIA 10 ~ 220mmHg
- MEAN 20 ~ 240mmHg
Pediatric :
- SYS 40 ~ 220mmHg
- DIA 10 ~ 160mmHg
- MEAN 20 ~ 170mmHg
Neonatal :
- SYS 40 ~ 135mmHg
- DIA 10 ~ 100mmHg
- MEAN 20 ~ 110mmHg
Static pressure measurement
Range: 0 ~ 300mmHg
Accuracy: ± 3mmHg
Resolution: 1mmHg Accuracy:
Max. Mean Error: ± 5mmHg
Max. Standard Deviation: 8mmHg
Overpressure protection:
- Adult 300mmHg
- Pediatric 240mmHg
- Neonatal 150mmHg
SPO2 :
Measurement range: 0 ~ 100%
Resolution: 1%
Accuracy: 70% ~ 100% ± 2%
40% ~ 69% ± 3%
Environment :
Operating environment :
- Temperature: 0 ~ 40 ℃
- Humidity: 15% ~ 80%
- Pressure: 86.0 kPa ~ 106.0kPa
Transport and Storage environment :
- Temperature: -20 ~ 55 ℃
- Humidity: 10% ~ 90%
- Pressure: 86.0 kPa ~ 106.0kPa
Specifications :
Product Name | Yonker YK-8000C Multipara Patient Monitor |
Brand | Yonker |
Model | YK-8000C |
ECG Input | 3/5 wire ECG cable |
Lead section | I II III aVR, aVL, aVF, V |
Gain selection | *0.25, *0.5, *1, *2,Auto |
SPO2 display Type | Waveform, Data |
Measurement range | 0-100% |
Accuracy | ±2% (between 70%-100%) |
Respiration (Impedance & Nasal Tube) Measurement type | 0-150rpm |
Accuracy | ±1bm or ±5%, select the bigger data |
NIBP Test method | Oscillometer |
Philosophy | Adult, Pediatric and Neonate |
Measurement type | Systolic Diastolic Mean |
Measurement parameter | Automatic, Continuous measurement |
Measurement method Manual | mmHg or ±2% |
Display Type | 12.1 inch color LCD touch screen supports multiple language modes; |
Standard Parameters | ECG, RESP, SPO2, NIBP, PR, TEMP, IBP, ETCO2 |
Battery Type | Lithium-ion battery |
Yonkermed Website General Wards Patient Monitor 8000C
Yonker Patient Monitor : Specifications
Estimated Delivery
5-7 Days
Warranty
- 1 Year ,
- From Manufacturer
Brand/Manufacturer
Brand
Yonker
Product Specifications
Color
White
Product Name
Yonker YK-8000C Multipara Patient Monitor
Product Model
YK-8000C
Qty./BOX
1
Weight & Dimensions
Product Weight
5Kg
Display and User Interface
Screen Size (Diagonal)
- 12.1 Inch
Display Type
LCD
Power Supply & Battery
Battery Backup
4Hr.
Battery type
Lithium rechargeable battery
Yonker Patient Monitor : Product reviews